Please use this identifier to cite or link to this item: http://117.252.14.250:8080/jspui/handle/123456789/3301
Title: 17-Fabrication, Testing and Evaluation of Bellary type water level recorder.
Authors: James, E. V.
Chittaranjan, S.
Keywords: Bellary type water level
Issue Date: 1987
Publisher: National Institute of Hydrology
Abstract: Automatic water level recorders are essential in the soil and water conservation and hydrological research. There is an urgent need to design and fabricate indigenous recorders, eliminating some of the constraints of the imported ones, such as the necessity of daily resetting the chart/stylus pen, frequent slips of the beaded wire, clogging and twisting of stylus pen etc., so as to record the runoff events accurately, instead of depending on the costly and imported water level recorders, involving considerable foreign exchange and time. To achieve this object, efforts made at the CS and WCR and TI, Research Centre, Bellary, have resulted in the development of a recorder and is found to work satisfactorily.
URI: http://117.252.14.250:8080/jspui/handle/123456789/3301
Appears in Collections:National Symposium on Hydrology, 16-18 December 1987, Vol.- II at Roorkee

Files in This Item:
File Description SizeFormat 
17-Fabrication, Testing and Evaluation of Bellary type water level recorder..pdf2.53 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.